AnalysIR submitting a set of IR signals for AC units: Difference between revisions
Jump to navigation
Jump to search
(Created page with "Here you can find the instructions for submitting a set of signals to use for adding support in AnalysIR. '''Steps:''' # In AnalysIR record a full set of signals # Include t...") |
No edit summary |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
Here you can find the instructions for submitting a set of signals to use for adding support in AnalysIR. | Here you can find the instructions for submitting a set of signals to use for adding support in AnalysIR. | ||
'''Steps:''' | '''Steps for AIR Conditioner signal or similar:''' | ||
# In AnalysIR record a full set of signals | # In AnalysIR record a '''full set of signals''' | ||
# When recording, keep the remote about 1->2m away from the receiver and point directly at it. | |||
# Include temperatures from 16degC to 30degC, in order. (or equivalent in degF) | # Include temperatures from 16degC to 30degC, in order. (or equivalent in degF) | ||
# Include ON & OFF signals | # Include ON & OFF signals | ||
Line 9: | Line 10: | ||
# It is important to change only 1 setting between each signal recorded | # It is important to change only 1 setting between each signal recorded | ||
# Include any additional signals you think might be useful. | # Include any additional signals you think might be useful. | ||
# Do not 'clean' the signals before sending (unless requested to) | |||
# Save the session via '''''Menu->File->Save Session''''' and email the file to us (or use the '''''Contact us''''' link on the wiki or website) | # Save the session via '''''Menu->File->Save Session''''' and email the file to us (or use the '''''Contact us''''' link on the wiki or website) | ||
# We will examine your signals and add support for them into AnalysIR. | # We will examine your signals and add support for them into AnalysIR. | ||
# We will then email an updated AnalysIR.ini file to you. Follow the Instructions here: [[AnalysIR updating config file]] | # We will then email an updated AnalysIR.ini file to you. Follow the Instructions here: [[AnalysIR updating config file]] | ||
'''Steps for non-AC signals:''' | |||
# Follow the steps above | |||
# ...and just record a set of signal that represent a reasonable set of the signals available. | |||
# Make sure to identify each signal in the button column of history. | |||
# Do not 'clean' the signals before sending (unless requested to) | |||
# Save & send the signals as above. | |||
Finally, make sure to include the make & model # of the device being controlled, the remote control and the equipment used to record the signals. (For AnalysIR supplied tools include only the name) |
Latest revision as of 08:56, 22 July 2023
Here you can find the instructions for submitting a set of signals to use for adding support in AnalysIR.
Steps for AIR Conditioner signal or similar:
- In AnalysIR record a full set of signals
- When recording, keep the remote about 1->2m away from the receiver and point directly at it.
- Include temperatures from 16degC to 30degC, in order. (or equivalent in degF)
- Include ON & OFF signals
- Make sure to record a description of the signal in the button column of History as you record each signal. (e.g. 16C)
- It is important to change only 1 setting between each signal recorded
- Include any additional signals you think might be useful.
- Do not 'clean' the signals before sending (unless requested to)
- Save the session via Menu->File->Save Session and email the file to us (or use the Contact us link on the wiki or website)
- We will examine your signals and add support for them into AnalysIR.
- We will then email an updated AnalysIR.ini file to you. Follow the Instructions here: AnalysIR updating config file
Steps for non-AC signals:
- Follow the steps above
- ...and just record a set of signal that represent a reasonable set of the signals available.
- Make sure to identify each signal in the button column of history.
- Do not 'clean' the signals before sending (unless requested to)
- Save & send the signals as above.
Finally, make sure to include the make & model # of the device being controlled, the remote control and the equipment used to record the signals. (For AnalysIR supplied tools include only the name)